cpti g4 samples Search Results


90
BIBUS METALS cpti g4 rod
( a ) SEM image of the surface morphology of commercially pure titanium Grade 4 <t>(CpTi</t> <t>G4)</t> substrate; ( b ) SEM image of the calcium phosphate (CaP) coating deposited at −3 V for 30 min at 20 °C; ( c ) SEM image of a selected microregion of CaP coating with the corresponding EDS map of Ti, Ca, and P element distribution; ( d ) Energy dispersive spectrum in the microregion of CaP coating.
Cpti G4 Rod, supplied by BIBUS METALS, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cpti+g4+samples/pmc07930999-91-1-10?v=BIBUS+METALS
Average 90 stars, based on 1 article reviews
cpti g4 rod - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

Image Search Results


( a ) SEM image of the surface morphology of commercially pure titanium Grade 4 (CpTi G4) substrate; ( b ) SEM image of the calcium phosphate (CaP) coating deposited at −3 V for 30 min at 20 °C; ( c ) SEM image of a selected microregion of CaP coating with the corresponding EDS map of Ti, Ca, and P element distribution; ( d ) Energy dispersive spectrum in the microregion of CaP coating.

Journal: Journal of Functional Biomaterials

Article Title: Long-Term Assessment of the In Vitro Corrosion Resistance of Biomimetic ACP Coatings Electrodeposited from an Acetate Bath

doi: 10.3390/jfb12010012

Figure Lengend Snippet: ( a ) SEM image of the surface morphology of commercially pure titanium Grade 4 (CpTi G4) substrate; ( b ) SEM image of the calcium phosphate (CaP) coating deposited at −3 V for 30 min at 20 °C; ( c ) SEM image of a selected microregion of CaP coating with the corresponding EDS map of Ti, Ca, and P element distribution; ( d ) Energy dispersive spectrum in the microregion of CaP coating.

Article Snippet: A CpTi G4 rod with a diameter of 10 mm (Bibus Metals, Dąbrowa, Poland) was cut into disk-shaped samples which were 5 mm high.

Techniques:

The roughness profile and the distribution histogram of the profile heights: ( a ) CpTi G4 substrate subjected to sandblasting and autoclaving; ( b ) ACP coating deposited at −3 V for 30 min at 20 °C.

Journal: Journal of Functional Biomaterials

Article Title: Long-Term Assessment of the In Vitro Corrosion Resistance of Biomimetic ACP Coatings Electrodeposited from an Acetate Bath

doi: 10.3390/jfb12010012

Figure Lengend Snippet: The roughness profile and the distribution histogram of the profile heights: ( a ) CpTi G4 substrate subjected to sandblasting and autoclaving; ( b ) ACP coating deposited at −3 V for 30 min at 20 °C.

Article Snippet: A CpTi G4 rod with a diameter of 10 mm (Bibus Metals, Dąbrowa, Poland) was cut into disk-shaped samples which were 5 mm high.

Techniques:

Bode diagrams for the sandblasted and autoclaved CpTi G4 and CpTi G4|TiO 2 |ACP electrodes in the artificial saliva solution (ASS) solution at 37 °C with the equivalent electrical circuit models for the pitting corrosion process used for CNLS-fitting: ( a ) Magnitude for the CpTi G4; ( b ) Magnitude for the CpTi G4|TiO 2 |ACP; ( c ) Phase angle for the CpTi G4; ( d ) Phase angle for the CpTi G4|TiO 2 |ACP; ( e ) One-CPE model; ( f ) Two-CPE model. Symbols are experimental data and continuous lines are CNLS fit.

Journal: Journal of Functional Biomaterials

Article Title: Long-Term Assessment of the In Vitro Corrosion Resistance of Biomimetic ACP Coatings Electrodeposited from an Acetate Bath

doi: 10.3390/jfb12010012

Figure Lengend Snippet: Bode diagrams for the sandblasted and autoclaved CpTi G4 and CpTi G4|TiO 2 |ACP electrodes in the artificial saliva solution (ASS) solution at 37 °C with the equivalent electrical circuit models for the pitting corrosion process used for CNLS-fitting: ( a ) Magnitude for the CpTi G4; ( b ) Magnitude for the CpTi G4|TiO 2 |ACP; ( c ) Phase angle for the CpTi G4; ( d ) Phase angle for the CpTi G4|TiO 2 |ACP; ( e ) One-CPE model; ( f ) Two-CPE model. Symbols are experimental data and continuous lines are CNLS fit.

Article Snippet: A CpTi G4 rod with a diameter of 10 mm (Bibus Metals, Dąbrowa, Poland) was cut into disk-shaped samples which were 5 mm high.

Techniques:

The dependence of the impedance module log| Z | at f = 0.1 Hz from immersion time for the sandblasted and autoclaved CpTi G4 and CpTi G4|TiO 2 |ACP electrodes in the ASS at 37 °C.

Journal: Journal of Functional Biomaterials

Article Title: Long-Term Assessment of the In Vitro Corrosion Resistance of Biomimetic ACP Coatings Electrodeposited from an Acetate Bath

doi: 10.3390/jfb12010012

Figure Lengend Snippet: The dependence of the impedance module log| Z | at f = 0.1 Hz from immersion time for the sandblasted and autoclaved CpTi G4 and CpTi G4|TiO 2 |ACP electrodes in the ASS at 37 °C.

Article Snippet: A CpTi G4 rod with a diameter of 10 mm (Bibus Metals, Dąbrowa, Poland) was cut into disk-shaped samples which were 5 mm high.

Techniques:

The parameters with standard deviations determined by approximation of the experimental EIS data for the sandblasted and autoclaved  CpTi G4  electrode in the ASS at 37 °C and the equivalent electrical circuit model for the pitting corrosion process (see <xref ref-type= Figure 3 e)." width="100%" height="100%">

Journal: Journal of Functional Biomaterials

Article Title: Long-Term Assessment of the In Vitro Corrosion Resistance of Biomimetic ACP Coatings Electrodeposited from an Acetate Bath

doi: 10.3390/jfb12010012

Figure Lengend Snippet: The parameters with standard deviations determined by approximation of the experimental EIS data for the sandblasted and autoclaved CpTi G4 electrode in the ASS at 37 °C and the equivalent electrical circuit model for the pitting corrosion process (see Figure 3 e).

Article Snippet: A CpTi G4 rod with a diameter of 10 mm (Bibus Metals, Dąbrowa, Poland) was cut into disk-shaped samples which were 5 mm high.

Techniques:

The parameters with standard deviations determined by approximation of the experimental EIS data for the  CpTi  G4|TiO 2 |ACP electrode in the ASS at 37 °C and the equivalent electrical circuit model for pitting corrosion process (see <xref ref-type= Figure 3 e,f)." width="100%" height="100%">

Journal: Journal of Functional Biomaterials

Article Title: Long-Term Assessment of the In Vitro Corrosion Resistance of Biomimetic ACP Coatings Electrodeposited from an Acetate Bath

doi: 10.3390/jfb12010012

Figure Lengend Snippet: The parameters with standard deviations determined by approximation of the experimental EIS data for the CpTi G4|TiO 2 |ACP electrode in the ASS at 37 °C and the equivalent electrical circuit model for pitting corrosion process (see Figure 3 e,f).

Article Snippet: A CpTi G4 rod with a diameter of 10 mm (Bibus Metals, Dąbrowa, Poland) was cut into disk-shaped samples which were 5 mm high.

Techniques:

Anodic polarization curves at the polarization scan rate of v = 1 mV s −1 for the sandblasted and autoclaved CpTi G4 and CpTi G4|TiO 2 |ACP electrodes in the ASS at 37 °C after days 1 and 21 of immersion.

Journal: Journal of Functional Biomaterials

Article Title: Long-Term Assessment of the In Vitro Corrosion Resistance of Biomimetic ACP Coatings Electrodeposited from an Acetate Bath

doi: 10.3390/jfb12010012

Figure Lengend Snippet: Anodic polarization curves at the polarization scan rate of v = 1 mV s −1 for the sandblasted and autoclaved CpTi G4 and CpTi G4|TiO 2 |ACP electrodes in the ASS at 37 °C after days 1 and 21 of immersion.

Article Snippet: A CpTi G4 rod with a diameter of 10 mm (Bibus Metals, Dąbrowa, Poland) was cut into disk-shaped samples which were 5 mm high.

Techniques:

Work function ( WF ) maps: ( a ) Sandblasted and autoclaved CpTi G4 substrate before immersion in the ASS; ( b ) Sandblasted and autoclaved CpTi G4 after 21 days of immersion in the ASS; ( c ) ACP-coated CpTi G4 before immersion in the ASS; ( d ) ACP-coated CpTi G4 after 21 days of immersion in the ASS.

Journal: Journal of Functional Biomaterials

Article Title: Long-Term Assessment of the In Vitro Corrosion Resistance of Biomimetic ACP Coatings Electrodeposited from an Acetate Bath

doi: 10.3390/jfb12010012

Figure Lengend Snippet: Work function ( WF ) maps: ( a ) Sandblasted and autoclaved CpTi G4 substrate before immersion in the ASS; ( b ) Sandblasted and autoclaved CpTi G4 after 21 days of immersion in the ASS; ( c ) ACP-coated CpTi G4 before immersion in the ASS; ( d ) ACP-coated CpTi G4 after 21 days of immersion in the ASS.

Article Snippet: A CpTi G4 rod with a diameter of 10 mm (Bibus Metals, Dąbrowa, Poland) was cut into disk-shaped samples which were 5 mm high.

Techniques:

Statistical parameters calculated using work function ( WF ) maps of the sandblasted and autoclaved CpTi G4 and ACP-coated  CpTi G4.  WF av is the arithmetic average, WF a is the arithmetic mean deviation, WF rms is the root mean square deviation, WF sk is the skewness, and WF ku is the kurtosis.

Journal: Journal of Functional Biomaterials

Article Title: Long-Term Assessment of the In Vitro Corrosion Resistance of Biomimetic ACP Coatings Electrodeposited from an Acetate Bath

doi: 10.3390/jfb12010012

Figure Lengend Snippet: Statistical parameters calculated using work function ( WF ) maps of the sandblasted and autoclaved CpTi G4 and ACP-coated CpTi G4. WF av is the arithmetic average, WF a is the arithmetic mean deviation, WF rms is the root mean square deviation, WF sk is the skewness, and WF ku is the kurtosis.

Article Snippet: A CpTi G4 rod with a diameter of 10 mm (Bibus Metals, Dąbrowa, Poland) was cut into disk-shaped samples which were 5 mm high.

Techniques: